{"product_id":"lenovo-7zt7a00534-network-card-internal-ethernet-1000-mbits-7zt7a00534","title":"Lenovo 7ZT7A00534 network card Internal Ethernet 1000 Mbit\/s","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eVXLAN\/NVGRE Hardware Offloads: These stateless offloads preserve application performance for overlay networks. With these offloads, it is possible to distribute network traffic across CPU cores. At the same time, X710 offloads LSO, GSO, and checksum from the host software, which reduces CPU overhead\u003c\/li\u003e\n\u003cli\u003eMobile and cloud application acceleration: Intel’s Data Plan Development Kit (DPDK) delivers an open driver where users can fine-tune small packet performance, which delivers line-rate at 128 byte, and near line-rate at 64 byte\u003c\/li\u003e\n\u003cli\u003eLow latency: Intel Ethernet Flow Director delivers hardware-based application steering and Intel Data Direct I\/O makes the processor cache the primary destination and source of I\/O data rather than main memory. Combined, latency is reduced and Intel reports a three-fold improvement in RPS\u003c\/li\u003e\n\u003cli\u003eVirtualization performance: With Intel Virtualization Technology (VT), the X710 family of adapters delivers outstanding I\/O performance in virtualized server environments. These adapters reduce I\/O bottlenecks by providing intelligent offloads for networking traffic per virtual machine (VM), which enables near-line rate speeds for small packets and supports almost an unlimited amount of isolated traffic flows so that you can scale your cloud environment\u003c\/li\u003e\n\u003cli\u003eNext-generation VMDq: The X710 adapters support up to 256 VMDq VMs and offer enhanced Quality of Service (QoS) feature by providing weighted round-robin servicing for the Tx data. The adapters offload the data-sorting functionality from the hypervisor to the network silicon, which improves data throughput and CPU usage\u003c\/li\u003e\n\u003cli\u003ePCI-SIG SR-IOV implementation: Provides an implementation of the PCI-SIG standard for I\/O Virtualization. The physical configuration of each port is divided into multiple virtual ports. Each virtual port is assigned to an individual VM directly by bypassing the virtual switch in the Hypervisor, which results in near-native performance\u003c\/li\u003e\n\u003cli\u003eVM load balancing: Provides traffic load balancing (Tx and Rx) across VMs that are bound to the team interface. It also provides fault tolerance if a switch, port, cable, or adapter fails\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003eThe Intel X710 family of 10 Gigabit Ethernet (GbE) server network adapters addresses the demanding needs of the next-generation data center. By providing unmatched features for server and network virtualization, small packet performance, and low power; the data center network is flexible, scalable, and resilient.\u003cbr\u003e\u003cbr\u003eThe X710 is available in three host connections: a standard PCIe host interface, a Mezzanine LOM (ML2) host interface for ThinkSystem and System x servers, and an AnyFabric host interface for ThinkServer systems.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet LAN (RJ-45) ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost interface\u003c\/td\u003e\n\u003ctd\u003ePCI Express\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity technology\u003c\/td\u003e\n\u003ctd\u003eWired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eBandwidth\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum data transfer rate\u003c\/td\u003e\n\u003ctd\u003e1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eGreen, Silver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWake-on-LAN ready\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceive Side Scaling (RSS)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntelligent Offloads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel® Virtualization Technology (Intel® VT)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Virtual Machine Device Queues (VMDq)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Data Direct I\/O Technology\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per pack\u003c\/td\u003e\n\u003ctd\u003e1 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eNetwork\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN tagging\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eiSCSI support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q, IEEE 802.1ad, IEEE 802.1as, IEEE 802.1p, IEEE 802.3ae, IEEE 802.3x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWake-on-LAN ready\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum data transfer rate\u003c\/td\u003e\n\u003ctd\u003e1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eGreen, Silver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEN55022\nEN55024\nEN 61000-3-2\nEN 61000-3-3\nICES-003, Issue-004\nFCC 47 CFR Part 15 Class A\nVCCI\nAS\/NZS CISPR 22 \/ C-tick\nRRL for KC\nBSMI\nUL 94 V-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eSystem requirements\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible operating systems\u003c\/td\u003e\n\u003ctd\u003eMicrosoft Windows Server 2008 R2\nMicrosoft Windows Server 2012\nMicrosoft Windows Server 2012 R2\nMicrosoft Windows Server 2016\nRed Hat Enterprise Linux 6 Server x64 Edition\nRed Hat Enterprise Linux 7\nSUSE Linux Enterprise Server 11 for AMD64\/EM64T\nSUSE Linux Enterprise Server 11 with Xen for AMD64\/EM64T\nSUSE Linux Enterprise Server 12\nSUSE Linux Enterprise Server 12 with XEN\nVMware vSphere 5.5 (ESXi)\nVMware vSphere 6.0 (ESXi)\nVMware vSphere 6.5 (ESXi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-20 - 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e10 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 2134 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWake-on-LAN ready\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceive Side Scaling (RSS)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntelligent Offloads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel® Virtualization Technology (Intel® VT)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Virtual Machine Device Queues (VMDq)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Data Direct I\/O Technology\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per pack\u003c\/td\u003e\n\u003ctd\u003e1 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEN55022\nEN55024\nEN 61000-3-2\nEN 61000-3-3\nICES-003, Issue-004\nFCC 47 CFR Part 15 Class A\nVCCI\nAS\/NZS CISPR 22 \/ C-tick\nRRL for KC\nBSMI\nUL 94 V-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible operating systems\u003c\/td\u003e\n\u003ctd\u003eMicrosoft Windows Server 2008 R2\nMicrosoft Windows Server 2012\nMicrosoft Windows Server 2012 R2\nMicrosoft Windows Server 2016\nRed Hat Enterprise Linux 6 Server x64 Edition\nRed Hat Enterprise Linux 7\nSUSE Linux Enterprise Server 11 for AMD64\/EM64T\nSUSE Linux Enterprise Server 11 with Xen for AMD64\/EM64T\nSUSE Linux Enterprise Server 12\nSUSE Linux Enterprise Server 12 with XEN\nVMware vSphere 5.5 (ESXi)\nVMware vSphere 6.0 (ESXi)\nVMware vSphere 6.5 (ESXi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceive Side Scaling (RSS)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntelligent Offloads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel® Virtualization Technology (Intel® VT)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Virtual Machine Device Queues (VMDq)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntel Data Direct I\/O Technology\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity per pack\u003c\/td\u003e\n\u003ctd\u003e1 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Lenovo","offers":[{"title":"Default Title","offer_id":54048905560397,"sku":"7ZT7A00534","price":406.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6086\/2285\/files\/bSOBmIHeBUmE5A48fTqGoQ.c-m.jpg?v=1780808627","url":"https:\/\/thomby.co.uk\/products\/lenovo-7zt7a00534-network-card-internal-ethernet-1000-mbits-7zt7a00534","provider":"Thomby | Great Tech at Great Prices","version":"1.0","type":"link"}